S213
|
Measuring range (ÃøÁ¤¹üÀ§)
|
Resolution(ÇØ»óµµ)
|
Accuracy (Á¤È®µµ)
|
pH
|
-2.000 ¡¦ 20.000
|
0.001/0.01/0.1
|
¡¾0.002
|
mV
|
-2000.0 ¡¦ 2000.0
|
0.1/1
|
¡¾0.1 mV in -1000 ¡¦ 1000 mV; ¡¾0.2 mV outside
|
Rel. mV
|
-2000.0 ¡¦ 2000.0
|
0.1/1
|
¡¾0.1 mV in -1000 ¡¦ 1000 mV; ¡¾0.2 mV outside
|
Conductivity (ÀüµµÀ²)
|
0.001 ¥ìS/cm ¡¦ 1000 mS/cm
|
0.001 ¡¦ 1
|
¡¾ 0.5%
|
TDS
|
0.00 mg/L...1000 g/L
|
0.01 ¡¦ 1
|
0.01 ¡¦ 1
|
Salinity (¿°µµ)
|
0.00¡¦ 80.00 psu/ppt
|
0.00 ¡¦ 1.0
|
¡¾ 0.5%
|
Resistivity (ÀúÇ×·Â)
|
0.00¡¦100.0 M¥Ø•cm
|
0.00 ¡¦ 1.0
|
¡¾ 0.5%
|
Conductivity ash (Àüµµ¼º ȸºÐ)
|
0.000¡¦2022%
|
0.001 ¡¦ 1
|
¡¾ 0.5%
|
Temperature MTC/ATC
|
-5.0 (-30.0) ... 130.0 ¡ÆC (MTC) ATC
|
0.1 ¡ÆC
|
¡¾ 0.1 ¡ÆC
|
Calibration
(´«±Ý/º¸Á¤)
|
Calibration points (º¸Á¤ ÁöÁ¡)
|
Conductivity 1; pH Max. 5
(ÀüµµÀ²1; pH ÃÖ´ëÄ¡. 5)
|
Cond. Standards and Buffer groups
(ÄÁµð¼Ç; Ç¥ÁØ/ ¿ÏÃæ±º)
|
8 pre-defined pH buffers and 13 pre-defined
|
Buffer recognition
|
1 user defined each
(»ç¿ëÀÚÁ¤ÀÇ)
|
Isopotential point (µîÀüÀ§Á¡)
|
pH 7.00
|
Temperature capture
|
Automatic and manual
(ÀÚµ¿/ ¼öµ¿)
|
Calibration reminder
(º¸Á¤ ¾Ë¸²)
|
User-configurable (»ç¿ëÀÚ ¼³Á¤)
|
Electrode status icon
(Àü±Ø »óÅÂ
¾ÆÀÌÄÜ)
|
Shows quality of last calibration
(¸¶Áö¸· º¸Á¤ÀÇ »óÅ ǥ½Ã)
|
Manual input of cell constant
(¼¼Æ÷ »ó¼öÀÇ ¼öµ¿ ÀÔ·Â)
|
Yes
|
Display of cell constant
(¼¼Æ÷»ó¼öÀÇ Ç¥½Ã)
|
In Conductivity and dual channel mode
(Àüµµ¼º ¹× ÀÌÁß Ã¤³Î¸ðµå)
|
Measurement
(ÃøÁ¤)
|
Choice of endpoint formats
(Á¾Á¡ ±¸¼º¹æ½ÄÀÇ ¼±ÅÃ)
|
Automatic, manual, timed
(ÀÚµ¿, ¼öµ¿, ½Ã°£Á¦)
|
Choice of stability criteria (pH only)
(¾ÈÁ¤¼º ±âÁØ ¼±ÅÃ)
|
Fast, standard, strict
|
Choice of pH decimal places
(pH ¼Ò¼öÁ¡ ¼±ÅÃ)
|
1.111, 1.11, 1.1
|
Temperature capture
(¿ÂµµÄ¸ÃÄ)
|
Automatic and manual
(ÀÚµ¿/ ¼öµ¿)
|
Serial measurements
(¿¬¼ÓÃøÁ¤)
|
Time interval, user-configurable (½Ã°£Á¦, »ç¿ëÀÚÁ¤ÀÇ)
|
Choice of reference temperature
(¿Âµµ ÀúÇ×·Â ¼±ÅÃ)
|
20 ¡ÆC or 25 ¡ÆC
|
Choice of temperature compensation
(¿Âµµº¸»óÀÇ ¼±ÅÃ)
|
Linear, non-linear, off, pure-water
|
System and GLP
|
Menu guidance
(¼³¸í¼¸Þ´º)
|
12 languages (12°¡Áö ¾ð¾îÁö¿ø)
|
Display color scheme
(Ç¥½Ãâ »ö»ó)
|
Blue, red, green, grey
|
Time and date
(½Ã°£ ¹× ³¯Â¥)
|
2 time formats, 4 date formats
(2°³ÀÇ ½Ã°£Çü½Ä, 4°³ÀÇ ³¯Â¥»óÅÂÁö¿ø)
|
PIN protection
(PIN º¸È£)
|
Login, deletion of data, system settings
(·Î±×ÀÎ, ³¯Â¥»èÁ¦, ȯ°æ¼³Á¤)
|
Measurement limits
(ÃøÁ¤Á¦ÇѹüÀ§)
|
User-defined
(»ç¿ëÀÚÁ¤ÀÇ)
|
Instrument modes
(°èÃø±â¸ðµå)
|
Routine mode / expert mode
(ÁÖ±âÀû¸ðµå, Àü¹®°¡¸ðµå)
|
ID input
(ÀÔ·Â ID)
|
User ID, sample ID, sensor ID, sensor
|
ID input automation
(ÀÔ·Â ID ÀÚµ¿)
|
Barcode reader and keyboard (USB)
|
Regulations
|
Pure & ultra-pure water (Ãʼø¼ö)
|
USP/EP compliant
|
Bioethanol
(¹ÙÀÌ¿À¿¡Åº¿Ã)
|
ABNT NBR 10547:2006
|
Sugar analysis
(´çºÐ ºÐ¼®)
|
ICUMSA GS2/3-17 and GS 1/3/4/7/8-13
|
Data processing
(µ¥ÀÌÅͰúÁ¤)
|
Data storage
(µ¥ÀÌŸÀúÀå)
|
2000 measurements
|
Print formats
(Ãâ·ÂÇüÅÂ)
|
Short, normal, GLP
|
Data Export
(µ¥ÀÌÅͼÛÃâ)
|
USB-stick, EasyDirect pH PC software
|
Connectors
(¿¬°áÀåÄ¡)
|
pH Sensor input
(pH¼¾¼)
|
BNC (impedance > 3x1012 ¥Ø)
|
Temperature sensor input
(¿Âµµ¼¾¼)
|
Cinch/RCA (NTC30 k¥Ø or Pt1000)
|
Reference input
(Ç¥ÁØ)
|
2 mm Ref.
|
Digital sensor input
(µðÁöÅÐ ¼¾¼)
|
Mini-LTW
|
Conductivity input
(Àüµµ¼º)
|
Mini-DIN
|
Conductivity input
|
RS232, USB-A, USA-B
|
Stirrer connector
(±³¹Ý±â ¿¬°áÀåÄ¡)
|
Mini-DIN
|
General
|
Power requirements
(ÇÊ¿äÀü·Â)
|
DC 9–12 V/ 2.5 W
|
Size/weight
(Å©±â/¹«°Ô)
|
204 x 174 x 74 mm, 890 g
|
Display
(Ç¥½Ãâ)
|
Color TFT
|
Ambient conditions
(ȯ°æÁ¶°Ç)
|
Temperature
(¿Âµµ)
|
5 ¡¦ 40 ¡ÆC
|
Relative humidity
(ÁÖº¯½Àµµ)
|
5 ¡¦ 80% (non-condensing)
|
Installation category
|
II
|
Pollution degree
(¿À¿°Á¤µµ)
|
2
|
Altitude
(°íµµ)
|
Up to 2000 m above sea level
|
Protection level
(º¸È£·¹º§)
|
IP54
|
Housing
|
ABS/PC reinforced
|
Window
|
Polymethyl methacrylate (PMMA)
|
Keypad
|
Membrane keypad: Polyethylene terephthalate (PET)
|