- ÃÖ´ë 2°³ ¼¾¼(¼öÀ§, ¿Âµµ, Àü±âÀüµµµµ, pH, ORP, »ê¼Ò, ʵµ, ¾Ï¸ð´Ï¾Æ, Áú»ê¿°, ¿°È¹°, ¾Ï¸ð´½, ³ªÆ®·ý, Ä®½·,
ºÒ¼Ò, Ä®·ý, hlorophyll or cyano-bacteria-rhodamine WT µî) ¼ö¿ë
- KLL-Q-2 ¸ð¹ÙÀÏ ÇöÀå ¿¬±¸½Ç °ú °áÇÕµÈ Ãß°¡ Àü±â Á¢Á¡ °ÔÀÌÁö ±â´É
- ÃÖÀûÈµÈ µðÀÚÀÎ(¨ª 89mm, ±æÀÌ 572mm), Á÷°æ 4 ÆÄÀÌÇÁºÎÅÍ »ç¿ë °¡´É
- Output : RS485(SHWP), ¿É¼Ç : MODBUS, SDI-12, 0/4-20mA
- ¿É¼Ç: ÅëÇÕµÈ °í¼º´É SEBA µ¥ÀÌÅÍ ·Î°Å Qualilog16(°íÁ¤ »ç¿ë¿ë)
Water level [cm], [m] |
Sensor : Relative pressure probe Measurement principle: Capacitive with ceramic measurement cell Measuring range: 0-2 / 1 /4 /5 /20 /40 / 100/ 200m water column or according to specifications Measuring accuracy : ¡¾ 0.1% FS Long-term stability : ¡¾ 0.1% / year |
Water temperature [¡ÆC] |
Sensor : NTC30 with polynomial linearisation Measurement principle :NTC resistor Measuring range:-5 - +50¡ÆC Measuring accuracy : 0.1¡ÆC Dissolution : 0.01¡ÆC Pressure Range : 0-50 bar
|
Conductivity [µS/cm], [mS/cm] / Derived parameters: solutes [g/l], salinity, density [g/l] |
Sensor : 4-electrode measuring cell Measuring range : 0-200mS / cm (total) automatic Measuring range switching: 0-200¥ìS / cm; 0.2-2mS / cm; 2-20 mS / cm; 20-200 mS / cm Measuring accuracy : ¡¾ 1¥ìS / cm at measuring range 0-200¥ìS / cm; +/- 0.5% with measuring range 0.2-200mS Dissolution: 0.0001mS/cm Temperature : -5¡ÆC-50¡ÆC Pressure Range : 0-50 bar |
pH value [pH] |
Sensor: Glass electrode Measuring range : 0-14pH Measuring accuracy : ¡¾ 0.1pH Dissolution : 0.01 pH Temperature : 0-50¡ÆC Pressure Range: 0-20 bar |
Redox [mV] |
Sensor : Glass electrode Measuring range : -1200mV-1200mV Measuring accuracy : ¡¾ 10mV Dissolution: 0.1mV Temperature : 0-50¡ÆC Pressure Range : 0-20 bar |
Oxygen [mg/l] |
Sensor : Derived parameters: oxygen saturation [%] / Clark electrode (amperometric) Measuring range :0-40mg Measuring accuracy:¡¾ 0.5% FS Dissolution : 0.01 mg/l Temperature : 0-50¡ÆC Pressure Range: 0-10 bar |
Oxygen [mg/l] |
Sensor :Optical Measuring range : 0-25mg/l (at 25¡ÆC, 1013hPa) / 0-40mg/l (at 3¡ÆC, 1013hPa) Measuring accuracy : ¡¾ 0.5% FS Dissolution : 0.001mg/l Temperature : -5¡ÆC-50¡ÆC Pressure Range : 0-12 bar |
Turbidity [NTU] / Derived parameters: suspended solids [mg/l] |
Sensor : Optical, Derived parameters : Suspended substances [mg / l] optically Measuring range : 0-1000 NTU and 0-5000 NTU Measuring accuracy :¡¾ 1% of the respective end of measuring range Dissolution : ¡¾ 0.0125% of the respective end of measuring range Temperature: 0-50¡ÆC Pressure Range :0-10 bar (with wiper) / 0-20bar (without wiper) |
|
|
ÀçÁú |
PVC-U |
±Ô°Ý |
¨ª89mm, length: 572mm |
ÇÁ·Îºê |
IP68 |
RS485 interface |
IP67 (immersion depth with dry cartridge up to 3m, depending on cable length) |
Outputs |
RS485 (SHWP) standard, MODBUS, SDI-12, 4-20mA (Optional) |
Communications Interface |
RS485 |
Power supply |
4-15VDC or 8-15VDC with optical sensors |
ÀÛµ¿ ¿Âµµ |
Parameter-dependent |
±íÀÌ |
up to 1000m |
»óǰÁ¤º¸°í½Ã
Á¦Ç°¸í |
´ÙÇ׸ñ ¼öÁúÃøÁ¤±â µ¥ÀÌÅͷΰŠ/ Qualilog-16 |
ÆÇ¸Å°¡°Ý |
200,000¿ø |
¹Ýǰ±³È¯ |
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆÇ¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óǰ±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.
!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óǰ °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹Ýǰ½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù. |
¹è¼Û¾È³» |
°áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óǰÀ» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç KG·ÎÁö½ºÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà Åù蹫·á¹è¼ÛÀÔ´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
ȹ°(¿ë´Þ),Äü ÀÌ¿ëÀº ±¸¸ÅÀÚ²²¼ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.
|
°áÁ¦¾È³» |
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù. |