<Æ®·£½º¹ÌÅÍ> |
|
ä³Î¼ö |
48 electrodes |
Current modulation |
0.001 ~ 0.4 A Resolution > 120 µA |
Current measurement |
Resolution: 1 µA Stability: 0.0025% VM Accuracy: > 60 µA |
|
|
<¸®½Ã¹ö> |
|
Measurement scale |
N.2 with automatic scale change |
Protections |
Automatic filtering at 50 and 60 Hz |
Input impedance |
1.6 * 1010 §Ù |
Scale ¡¾ 0.47V |
• Resolution: 1 µV • Stability > 0,12% VM • Accuracy: 70 µV |
Scale ¡¾ 4.7 V |
• Resolution: 10 µV • Stability: > 0.03% VM • Accuracy: 700 µV |
|
|
<³»ºÎ ¿Âµµ ÃøÁ¤> |
|
Measurement points |
N.2 on electronic board and on heat sink |
Range |
-55...150 ¡ÆC |
Resolution |
0.1 ¡ÆC |
Accuracy |
¡¾ 0.3 ¡ÆC |
|
|
<Supply> |
|
From PV module |
50 Wp (optimized for one survey per day, performance site depending on latitude and insolation conditions) |
From main grid |
115/230 V AC, 50/60 Hz |
Back-up battery |
40 Ah |
Additional sources |
Additional battery pack (on demand) |
Protection fuses |
N. 6 of 12 V power lines |
Energy consumption |
• 150 mW low power mode, modem/router off • 5 W low power mode, modem/router active • 7 W standby, modem/router active • 115 W max during measurement at maximum power |
Nominal energy autonomy |
10 days, considering: • Using a fully charged 40 Ah battery • Supplementary power module missing • Complete absence of sun • Low power mode enabled • Execution of one survey per day lasting 40 minutes and with an average injection power of 60 W |
|
|
<¹Ú½º> |
|
Material |
Heat molded and glass fiber reinforced polyester |
Dimensions |
730 x 530 x 270 mm (external connectors excluded) |
Weight (without battery) |
13.5 kg |
Battery weight |
13.5 kg |
Protection grade |
IP66 |
|
|
<ÄÉÀ̺í> |
|
Resistance to chemical agents |
• solutions of ammonia and biogas • ozone, UV rays and atmospheric agents according to EN 50396 and HD 605 S3 |
Usage environments |
Industrial environments, in chemical, composting and purifi- cation plants |
Conformity |
VDE 0250 / 0285, EN 50565-2 Norms |
Protection |
Anti-rodents (according to part number) |
Nominal voltage |
U0/U: 300/500 V |
Test voltage |
4000 V |
Operative temperature |
• Installation: -40...80 ¡ÆC • Fixed laying: -50...80 ¡ÆC |
|
|
<Àü±Ø> |
|
ÀçÁú |
½ºÅ×Àθ®½º½ºÆ¿ AISI 316 |
±Ô°Ý |
• Plate: 230 x 128 mm, width 1 mm • Picket: length 400 mm, diameter 10 mm |